PENENTUAN TORSI MINIMUM PENGGERAK ELEKTROMEKANIK KATUP PA-01/02/03 AA001/003 SISTEM PENDINGIN SEKUNDER RSG-GAS
DOI: http://dx.doi.org/10.17146/bprn.2016.13.2.3895
Sari
ABSTRAK
PENENTUAN TORSI MINIMUM PENGGERAK ELEKTROMEKANIK KATUP PA-01/02/03 AA003 PADA SISTEM PENDINGIN SEKUNDER RSG-GAS. Katup memegang peranan penting dalam pengoperasian reaktor nuklir. Sebagai pengatur aliran fluida, katup harus selalu dirawat. Pada perawatan katup yang menggunakan penggerak elektromekanik selain pengujian buka-tutup, juga pengaturan torsinya. Tujuan penulisan makalah yaitu untuk menghitung torsi pada katup sehingga dapat ditentukan torsi minimum yang diperlukan sebagai penggerak elektromekanik. Lingkup dibatasi pada perhitungan torsi katup sistem pendingin sekunder PA-01/02/03 AA003. Metode yang digunakan adalah dengan menghitung torsi, untuk mencari data aliran, mencari data spesifikasi katup, mencari data dimensi pipa, menghitung penurunan tekanan dan menghitung torsi.Dari hasil perhitungan diperoleh bahwa harga minimum torsi yang bekerja pada katup PA-01/02/03 AA003 sebesar(TT) = 3982,986 Nm = 3,983 kNm. Disimpulkan bahwa torsi ini dapat digunakan untuk pengaturan perawatan katup PA-01/02/03 AA003 RSG-GAS.
Kata kunci : Sistem pendingin sekunder, katup, torsi minimum
ABSTRACT
DETERMINATION OF MINIMUM TORQUE OF ELECTROMECHANICAL DRIVER OF THE PA-01/02/03 AA003 VALVE OF THE RSG-GAS SECONDARYCOOLING SYSTEM. Valve has an important role in the operation of nuclear reactor. As a fluid controller valve should be always maintenance. Beside the maintenance of valve using an electromechanical driver, the testing of opening and closing, as well as the torque setting should be pay attention. The purpose of writing this paper is to calculate of the torque of the valve so that it can be determined the minimum torque required as an electromechanical drive. The scope is limited on the calculation of the torque on the valve of PA-01/02/03 AA003 of the secondary coolant system. The method used for calculation is by calculating the torque of valve in order to find the flowdata, specification valves data, pipe dimensions data, calculate pressure drop and calculate torque. Calculation result is shown that minimum value of torque working on the valve PA-01/02/03 AA003 is (TT) is 3982.986 Nm or 3,983 kNm. It is can be concluded that torque can be used to control of maintenance setting of the PA-01/02/03 AA003 valve of the secondary cooling system of the RSG-GAS.
Keywords: secondary cooling system, valve, minimum torqueTeks Lengkap:
PDFRefbacks
- Saat ini tidak ada refbacks.
##submission.copyrightStatement##
Reaktor : Buletin Pengelolaan Reaktor Nuklir bekerjasama dengan: