EVALUASI PENGHEMATAN ENERGI DI INSTALASI RADIOMETA-LURGI PUSAT TEKNOLOGI BAHAN BAKAR NUKLIR

Abdul Latief

DOI: http://dx.doi.org/10.17146/urania.2010.16.1.2439

Sari


ABSTRAK

EVALUASI PENGHEMATAN ENERGI DI INSTALASI RADIOMETALURGI PUSAT TEKNOLOGI BAHAN BAKAR NUKLIR. Telah dilakukan evaluasi penghematan energi atau penghematan biaya pemakaian listrik Instalasi Radiometalurgi melalui penurunan daya, managemen operasi dan pemasangan kapasitor bank dengan tujuan untuk mengetahui sampai seberapa jauh parameter tersebut mempengaruhi penghematan biaya pemakaian listrik Instalasi Radiometalurgi (IRM) , Pusat Teknologi Bahan Bakar Nuklir (PTBN) setiap bulan. Lingkup penghematan  diantaranya melihat pengaruh penurunan daya, mengatur jumlah peralatan, pengurangan jam pengoperasian dan pemasangan kapasitor bank sehingga dapat diketahui kebutuhan energy riil LWBP (Luar Waktu Beban Puncak), WBP (Waktu Beban Puncak) dan kVARh (denda PLN) serta jumlah biayanya.  Metoda untuk mengetahui sampai seberapa besar penghematan pembayaran biaya listrik dilakukan dengan cara membandingkan biaya riil sebelum/setelah beban diturunkan dari 3.700 KVA menjadi 1.815 KVA, pengaruh pengurangan jam/jumlah peralatan yang beroperasi pada beban puncak /WBP(jam 18.00-22.00) dan LWBP serta kVARh setelah dipasang kapasitor bank terhadap penurunan biaya pembayaran listrik. Pengurangan energi/biaya pembayaran listrik di IRM dapat dilakukan dengan menurunkan daya dari 3.700 KVA menjadi1.815 KVA dan menghemat biaya Rp 39.360.255,- perbulan, pengurangan jam/jumlah peralatan yang beroperasi dapat menurunkan energy LWBP sebesar dari 208.994 menjadi 168.090 KWH perbulan , serta WBP turun dari 29.412 menjadi 17.880 KWH perbulan dan KVARh  turun dari 90.226 menjadi 9.652 KWH perbulan.

Kata kunci : Evalusi, pengheamatan energi.

 

ABSTRACT

EVALUATION OF ENERGY SAVINGS RADIOMETALURGY INSTALLATION (IRM), CENTER FOR NUCLEAR FUEL TECHNOLOGY (PTBN). The energy savings in installation Radiometalurgy or cost savings electrical consumption by reducing power, management operations in order to determine to what extent these parameters influence the cost savings on electricity usage in Radiometalurgi Installation (IRM) Center For Nuclear Fuel Technology (PTBN) each month. Scope of such savings, the influence of the power reduction, set the amount of equipment and hours of operation and to capasitor bank,so as to know the needs LWBP riel, WBP, kVARh and  payment of charges. Method to find out just how much electricity cost savings payments made by compare at the cost of riels before/after load is derived from a 3700 KVA to 1815 KVA, reducing the influence of hours / amount of equipment operating at peak load / WBP (hours 18.00-22.00) and LWBP of cost reduction electricity payments. The really need energy / electricity costs in the IRM payment is a reduction of power from 3.700 KVA to 1.815 KVA  save  Rp 39,360,255, -, reduction of hours/amount of equipment that can reduce energy operating LWBP registration from  208,994 to 168,090 KWH per month, WBP registration of .29.412 to 17.880 KWH per month and KVARh registration of 90,226 to 9,652 KWH per month.

Key word : Evaluation, energy saving.


Teks Lengkap:

PDF

Refbacks

  • Saat ini tidak ada refbacks.


Penerbit: Pusat Riset Teknologi Daur Bahan Bakar Nuklir dan Limbah Radioaktif 

Diindeks oleh:

   
     
      

p-ISSN 0852-4777 | e-ISSN 2528-0473