STUDI PENAMBAHAN PERISAI RADIASI DI KANAL HUBUNG S-5 UNTUK MENGURANGI PAPARAN LINGKUNGAN

Herry Mugirahardjo - Mugirahardjo, Sairun - -

Sari


ABSTRAK Telah dilakukan studi rencana penambahan perisai radiasi di atap kanal hubung S-5 dengan menggunakan bahan utama air. Tujuan penambahan perisai radiasi untuk mengurangi paparan pada atap kanal hubung S-5 agar pekerja radiasi tidak berpotensi menerima dosis radiasi melebihi Nilai Batas Dosis (NBD) yang diijinkan oleh BAPETEN, yaitu 20 mSv/tahun. Studi penambahan perisai radiasi dilakukan dengan membuat sebuah kolam pengukuran yang berukuran 8000(p)X2400(l)X300(t) mm3. Di dalam kolam ditentukan 9 titik pengukuran yang berjarak 1 meter. Pengukuran paparan radiasi, baik neutron maupun sinar-g, pada titik pengukuran dilakukan pada saat reactor beroperasi normal (15 MW), main shutter dan lithium shutter terbuka, dalam kondisi kolam belum diisi air, diisi air sedalam 15 cm dan 30 cm. Hasil pengukuran menunjukkan bahwa pada kedalaman air 30 cm paparan radiasi pada titik terdekat dengan sumber menurun dari 101,57 ɥSv/jam menjadi 1,09 ɥSv/jam untuk neutron dan 13.7 ɥSv/jam menjadi 3,95 ɥSv/jam untuk sinar γ. Paparan rad ini sudah tidak berpotensi menyebabkan pekerja radiasi mempunyai dosis melebihi NBD yang diijinkan oleh BAPETEN. Dari data pengukuran juga diperoleh data bahwa air sangat efektif untuk meredam radiasi neutron, tetapi kurang efektif untuk meredam radiasi sinar-g. Dari hasil studi rencana ini, akan dibuat perencanaan pembuatan perisai radiasi di atap kanal hubung S-5.

 

 

Kata kunci: perisai radiasi kanal hubung S-5, laju dosis S-5, paparan radiasi atap kanal hubung S-5

 

ABSTRACT ─ A study has been conducted for the addition of radiation shield on the roof of the S-5 canal using the main water material. The purpose of the adding a radiation shield is to reduce exposure to the S-5 canal roof so that radiation workers do not potentially receive radiation doses exceeding the Dose Limit (NBD) permitted by BAPETEN, ie 20 mSv/year. The study of the radiation shields additions was made by making a measuring pool with dimension 8000 X 2400 X 300 mm. Inside the pool is determined nine measurement point within 1 meter. Measurements of radiation exposure, both neutrons and g-rays, at the point of measurement are performed when the reactor operates normally (15 MW), the main shutter and open lithium shutter, in the condition the pool is not filled with water, filled with water as deep as 15 cm and 30 cm. The measurements showed that at a water depth of 30 cm the radiation exposure at the nearest point with the source decreased from 101.57 ɥSv/h to 1.09 ɥSv / h for neutrons and 13.7 ɥSv / hr to 3.95 ɥSv / h for γ rays. This radiation exposure has no potential to cause radiation workers to have a dose exceeding the NBD permitted by BAPETEN. From the measurement data also obtained data that water is very effective to reduce the radiation of neutrons, but less effective to reduce g-ray radiation. From the results of this study, will be made planning of radiation shielding on the roof of the S-5 canal.

 

Keywords: radiation shield S-5 canal, S-5 dose rate, radiation exposure of S-5 canal roof


Teks Lengkap:

PDF

Refbacks

  • Saat ini tidak ada refbacks.
slot gacor slot