PENGARUH UNSUR Al, Mg, DAN Na PADA ANALISIS URANIUM SECARA POTENSIOMETRI

Boybul ., Iis Haryati

Sari


ABSTRAK

PENGARUH UNSUR Al, Mg, DAN Na PADA ANALISIS URANIUM SECARA POTENSIOMETRI. Kadar uranium dalam larutan uranil nitrat hasil pelarutan pelat elemen bakar (PEB) U3O8-Al telah dianalisis dengan cara titrasi potensiometri. Penentuan kadar uranium dilakukan menggunakan metode reduksi-oksidasi dengan fero sulfat sebagai reduktor dan kalium bikromat sebagai oksidator. Larutan uranil nitrat hasil pelarutan mengandung unsur-unsur pengotor dengan kadar cukup tinggi. Untuk melihat adanya pengaruh unsur-unsur pengotor tersebut dilakukan preparasi sampel dengan teknik pemanasan menggunakan HClO4 dan preparasi sampel tanpa pemanasan. Hasil analisis uranium dalam larutan uranil nitrat hasil pelarutan pelat elemen bakar dengan teknik pemanasan dan tanpa pemanasan masing-masing sebesar 5,755 g/L dan 5,105 g/L. Adanya perbedaan hasil analisis yang cukup signifikan dari analisis tersebut dikarenakan di dalam larutan uranil nitrat terdapat unsur pengotor Al, Na, dan Mg dengan konsentrasi yang cukup tinggi. Dari percobaan yang dilakukan diketahui bahwa Al berpengaruh pada konsentrasi 8000 ppm dan 10 000 ppm dengan akurasi 96,35% dan 88,88%. Na berpengaruh pada konsentrasi 8000 ppm dan 10 000 ppm dengan akurasi 95,06% dan 87,09%. Sedangkan Mg berpengaruh pada konsentrasi 10 000 ppm dengan akurasi 96,23%. Pengaruh gabungan dari ketiga unsur-unsur tersebut dimulai masing-masing pada konsentrasi 1000 ppm, 2000 ppm dan 4000 ppm dengan akurasi 94,37%, 94,97%, dan 87,48%. Sedangkan pengaruh pada konsentrasi 6000 ppm atau lebih besar tidak bisa diukur.

KATA KUNCI: Potensiometri, analisis uranium, elemen bakar U3O8

ABSTRACT

THE INFLUENCE OF Al, Mg, AND Na ON URANIUM ANALYSIS USING POTENTIOMETRIC METHOD. The uranium concentration in uranyl nitrate solution from the dissolution of fuel element plate U3O8-Al has been analyzed using potentiometric method. The determination of uranium concentration is performed using redox method with ferro sulfate as the reductor and potassium bichromate as the oxidator. Uranyl nitrate solution obtained from the dissolution of fuel plate appears to contain impurities at relatively high concentration. To observe the influence of the impurities, sample preparation was perfomed employing heating with HClO4 and without heating. The results of uranium analysis in uranyl nitrate solution obtained from the dissolution of fuel elements plate with heating and without heating are 5.755 g/L and 5.105 g/L correpondingly. The difference in the analysis results is quite significant due to the presence of impurities Na, Mg and Al in the uranyl nitrate solution at rather high concentrations. The experiment results show that the influence of Al is noted at the concentrations of 8000 ppm and 10 000 ppm with accuracy of 95.06% and 87.09% respectively. The influence of Na is noted at the concentrations of 8000 ppm and 10 000 ppm with accuracy of 95.06% and 87.09%, respectively. The influence of Mg is noted at the concentration of 10 000 ppm with accuracy of 96.23%. The combined influence of the three elements commences at the concentrations of 1000 ppm, 2000 ppm, and 4000 ppm with accuracy of 94.37%, 94.97%, and 87.48% respectively. The combined influence at the concentration of 6000 ppm or higher cannot be measured.

 

FREE TERMS: potentiometry, uranium analysis, fuel element U3O8


Teks Lengkap:

PDF

Refbacks

  • Saat ini tidak ada refbacks.