ANALISIS KESELAMATAN RADIASI PADA KOLAM IRADIATOR “IZOTOP”

Petrus Zacharias, Abdul Jami

Sari


ABSTRAK

 

ANALISIS  KESELAMATAN  RADIASI  PADA KOLAM IRADIATOR  “IZOTOP”. Iradiator “Izotop” buatan Institute of Isotope Co.Ltd. Hungaria merupakan iradiator gamma panorama katagori IV yang dapat beroperasi secara kontinyu dan   batch. Kapasitas maksimum sumber gamma pada iradiator ini adalah 2 MCi. Kolam penyimpan sumber berukuran lebar 2,8 m, panjang 3,6 m, dan  kedalaman 6 m berisikan air bebas mineral. Rak sumber berukuran panjang 3 m dan tinggi 1 m. Jarak antara permukaan air kolam dan rak sumber menentukan fungsi air sebagai perisai radiasi. Konsep jarak ini digunakan untuk mengevaluasi   keselamatan radiasi kolam Iradiator “Izotop”. Pasal 8 dari SSG-8 IAEA digunakan sebagai referensi untuk analisis ini. Penentuan faktor  build–up air menggunakan Persamaan Taylor. Perhitungan laju dosis di atas kolam dilakukan untuk masing-masing tingkat permukaan  air, yaitu pada tingkat air normal, dan untuk setiap  0,3 m penurunan permukaan air  hingga penurunan sampai 1,5 m. Pada tingkat air normal sampai penurunan permukaan air 1,2 m, hasil perhitungan menunjukkan laju dosis sangat aman. Keadaan  laju dosis radiasi mencapai tingkat tidak aman ketika penurunan tingkat air  lebih dari 1,2 m. Hasil evaluasi ini memberikan gambaran bahwa desain kolam Iradiator “Izotop” dapat memenuhi    rekomendasi  IAEA.  Berdasarkan  rekomendasi ini,  pada  operasi  normal  iradiator gamma kategori IV, proses make – up air harus dilakukan ketika permukaan air berada di batas normal bawah, sehingga kejadian tidak aman tidak terjadi.

 

Kata kunci : Iradiator “Izotop”, kolam iradiator, laju dosis, keselamatan radiasi

 

 

ABSTRACT

 

RADIATION  SAFETY ANALYSIS  ON THE “IZOTOP” IRRADIATOR  POOL. “Izotop” Irradiator manufactured by Institute of Isotope Co. ltd. Hungary is a category IV panoramic gamma irradiators which can operate in both continuous and batch modes. The maximum gamma source capacity of the irradiator is 2 MCi. The dimension of the source storage pool containing demineralized water is about 6 m in deep, 2.8 m in wide and 3.6 m in length. The source rack is about 3 m in length and 1 m in height.  The distance between the surface of the pool water and the source rack defines the water as radiation shielding. The distance is used to evaluate the radiation safety of the “Izotop” Irradiator pool. Article 8 of the IAEA SSG-8 is used as reference for this analysis. Determination of water build-up factor uses Taylor's formula.  The calculation of the dose rate at the border of the pool was done for each of the water level, ie.  at the normal water level, and for each 0.3 m drop in water level decreasing until 1.5 m. At normal water levels, and up to 1.2 m of drop in water level, the result shows a very safe dose rate levels. The radiation dose rate reaches unsafe level  when the  water  level decreases more than  1.2  m.  The  results  of  this evaluation shows that “Izotop” Irradiators pool design can meet IAEA recommendations. Based on these recommendations, in normal operation of gamma irradiators category IV, the make - up of water shall be operated when the water level is in the normal low water level, so that the unsafe incidence will not happen.

 

Keywords: “Izotop” Irradiators, irradiator pool, dose rate, radiation safety.

Teks Lengkap:

PDF

Refbacks

  • Saat ini tidak ada refbacks.


slot gacor slot